SINO AGE DEVELOPMENT TECHNOLOGY, LTD.

Sino Age Development Technology Our products are your best choice in NDT and quality control field All products supplied by SADT have excellent quality and competitive price with our best service.

Manufacturer from China
Active Member
14 Years
Home / Products / Ultrasonic Thickness Gauge /

Portable MEC Backlight Ultrasonic Coating Thickness Gauge

Contact Now
SINO AGE DEVELOPMENT TECHNOLOGY, LTD.
City:beijing
Province/State:beijing
Country/Region:china
Contact Person:MsHu
Contact Now

Portable MEC Backlight Ultrasonic Coating Thickness Gauge

Ask Latest Price
Video Channel
Brand Name :SADT
Model Number :SA40+
Certification :CE ISO9001 SGS
Place of Origin :Beijing
MOQ :1pc
Price :USD200-400/pcs
Payment Terms :T/T in advance, Western Union
Supply Ability :50pcs/week
Delivery Time :Within 3 days after receiving payment
Packaging Details :Standard package
accuracy :0.01mm
memory :400
key words :ultrasonic thickness gauge price
Display :4 digits LCD
Measuring range :0.70~300.0mm in steel with PT-5 probe
Resolution :0.01mm@0.70~99.99mm, 0.1mm@100.0~300.0mm
Accuracy :0.70~9.99mm ±0.05mm / 10.00~99.99mm ±(0.5%+0.01)mm 100.0~300.0 ±(1%+0.1)mm
Unit :mm/inch
Velocity :1000~9999m/s
Memory :400 data
more
Contact Now

Add to Cart

Find Similar Videos
View Product Description

Portable Ultrasonic Thickness Gauge price SA40+ which can test thickness covered with coating


Introduction

SA40+ is the miniaturized ultrasonic thickness gauges that can measure wall thickness and velocity.

Using new technique of multiple echo(echo-to-echo), SA40+ can measure wall thickness under paint. For a normal ultrasonic thickness gauge, you must remove paint on work piece, but with new SA40+, you can take measurement directly over the paint of work piece and you can get real thickness value of work piece. SA40+ has two measuring modes: normal mode and multiple echo(MEC) mode. By normal mode, SA40+ is a normal ultrasonic thickness gauge; by MEC mode, SA40+ can measure over coatings.

Specifications

1) Technique: pulse echo with dual probe

2) Display: 4 digits LCD with backlight

3) Measuring range: 0.7 to 300.0mm

4) Resolution : 0.01mm 0.8-99.99mm, 0.1mm 100.0-300.0mm

5) Velocity range: 500-9999m/sec.

6) Display circle: 1 sec.

7) Coupling indication

8) Memory: 400 data can be stored and re-readable

9) Units: mm or inch

10) Low battery indicator on LCD

11) Auto shut-off: after 5 min. of non-use

12) Power: 2 ea. 1.5V AA alkaline cells

13) Operating temperature: 0-40°C

14) Operating humidity: 20-90%RH

15) Size: 124x67x30mm

16) Weight: 240g

Specificaiton:

Model

SA40+

Display 4 digits LCD
Backlight Yes
Measuring range 0.7.00~300.0mm in steel with standard probe (Normal mode)
3.00~20.00mm in steel
Thickness for coating: <1.2mm
(Coating mode)
Resolution 1.00~9.99mm ±0.05
10.00~99.99mm ±(0.5% H+0.01)
100.0~225.0 ±(1% H+0.1)
Unit
mm/inch
Velocity 1000~9999m/s
Coupling indicator Yes
Calibration Auto
Memory
40 data
Low battery indicator Yes
Working environment 0~40oC, 20~90%RH
Power off Auto
Power supply AA battery x 2
Net weight (g) 245
Dimension (mm) 124x67x30
Standard probe PT-5
Optional probes XT-5 / GT-5 / CT2.5

1.Thermal Material Measuring

Materials thickness with maximum 400℃ surface temperature could be measured using high temperature probe GT-5. Precautions: when measuring thermal materials:

Apply high temperature couplant, measure immediately after the couplant melts, the probe contact shall be less than 10 seconds and the interval between two measurements shall be no less than 1 minute.

Prevent the probe from being vibrated; otherwise the probe will be damaged.

When the temperature of thermal material increases 100℃, the velocity decreases about 1%. Correction needs to be done to the measuring values.

E.g.: we can define δ0 as the actual thickness of the material, δt as the display value in the instrument

Then:

When 125℃, δ 0 =δ t×0.99

When 225℃, δ 0 =δ t×0.98

When 325℃, δ 0 =δ t×0.97

Also, when we know accurately the material temperature to be measured, we can also correct the velocity of the instrument.

For example: under normal temperature (25℃), velocity of the material =5900 m/s,

When 125℃, velocity ≈5840m/s

When 225℃, velocity ≈5780m/s

When 325℃, velocity ≈5720m/s

Then, the displayed value is the actual value of the material.

Standard package

SA40+ main unit 1
Standard 5MHz probe PT-5 with
probe holder 1
Built-in calibration block 1
Coupling paste for normal temperature 1
Test certificate 1
Operation manual 1
Carrying case 1


Portable MEC Backlight Ultrasonic Coating Thickness GaugePortable MEC Backlight Ultrasonic Coating Thickness GaugePortable MEC Backlight Ultrasonic Coating Thickness GaugePortable MEC Backlight Ultrasonic Coating Thickness GaugePortable MEC Backlight Ultrasonic Coating Thickness GaugePortable MEC Backlight Ultrasonic Coating Thickness GaugePortable MEC Backlight Ultrasonic Coating Thickness GaugePortable MEC Backlight Ultrasonic Coating Thickness Gauge